The xenon lamp aging test chamber mainly uses 6.5KW long-arc water-cooled xenon lamp as the light source, and simulates the comprehensive conditions of light, heat and rainfall in the outdoor climate by changing and controlling the light irradiance, temperature (sample rack temperature, studio temperature), relative humidity, spray mode, etc., and conducts artificial accelerated aging test on the sample. The main control parameters are light irradiance, studio temperature, sample holder temperature, and relative humidity.
Ordering Information:
TR 6412 - Xeon Lamp Aging Test Chamber
Xenon arc lamp is a high-efficiency light source made by ultra-high pressure xenon discharge, which can be divided into long arc lamp and short arc lamp, and can be divided into water-cooled and air-cooled according to the cooling method, the use of water-cooled xenon lamp can simulate the outdoor daylight spectrum to the greatest extent and has a wider irradiation range, and the xenon lamp spectrum covers 250nm-3000nm. The TR 6412 Xeon Lamp Aging Test Chamber can provide twice the maximum irradiation intensity of the solar constant, meeting the requirements of stringent test standards.
GB | ISO international standards | ASTM American Standard for Materials | ||
GB/T 10485 | ISO 105-B02 | ASTM C1257 | ASTM D4434 | ASTM D6695 |
GB/T 12527 | ISO 105-B04 | ASTM C1442 | ASTM D4459 | ASTM D6878 |
GB/T 14522 | ISO 105-B06 | ASTM C1501 | ASTM D4637 | ASTM D750 |
GB/T 16259 | ISO 105-B07 | ASTM C1519 | ASTM D4798 | ASTM D7869 |
GB/T 16422 | ISO 105-B10 | ASTM C732 | ASTM D4811 | ASTM D904 |
GB/T 16991 | ISO 11341 | ASTM C734 | ASTM D5010 | ASTM F1164 |
GB/T 1865 | ISO 12040 | ASTM C793 | ASTM D5019 | ASTM F1515 |
GB/T 18833 | ISO 16474-1 | ASTM D1148 | ASTM D5071 | ASTM F2366 |
GB/T 29061 | ISO 16474-2 | ASTM D1670 | ASTM D5383 | ASTM G151 |
GB/T 32088 | ISO 18909 | ASTM D2565 | ASTM D5398 | ASTM G155 |
GB/T 5137 | ISO 18930 | ASTM D3424 | ASTM D5819 | SAE |
GB/T 6151 | ISO 18937 | ASTM D3451 | ASTM D6083 | AATCC |
GB/T 8427 | ISO 29664 | ASTM D4101 | ASTM D6551 | Other criteria |
GB/T 8430 | ISO 3917 | ASTM D4303 | ASTM D6577 | |
GB/T 3511 | ISO 4892-2 | ASTM D4355 | ASTM D6662 |
Project | Parameter |
Control mode | Automatic control of test factors |
light source | 6.5kW long arc water-cooled xenon lamp (imported light source) |
Lamp life | 3000-4000h (depending on the irradiance intensity setting used.) Regular lamp wash maintenance) |
Inner and outer filter hoods | It supports different combinations of internal and external filters such as daylight, window glass, and ultraviolet extension. |
Irradiance range | The highest irradiance equipment of 0.3W/m2~1.33 W/m2 (340mn) supports the highest intensity, and it is not recommended to test and use it for a long time. Control accuracy: ±0.01W/m2 |
The monitored wavelength of irradiance | 340nm、420nm或300nm~400nm |
Humidity range | Illumination: 10%~75% Darkness: Up to 100% ±3.0% |
Test chamber temperature range | 38℃~85℃ ±2.0℃ |
Rack temperature | Blackboard: 40°C~110°C Black mark: 40°C~120°C ±2.0℃ |
The sample was exposed to rain | √ |
Sample holder in the rain | √ |
Standard sample holders | 65个(145mm×70mm) |
Total area exposed | 6500cm2 |
Installation area | Automatic control of test factors |