TR 6010 series Drying Oven is a product produced by advanced laser and CNC machining equipment. It is widely used in industrial and mining enterprises, universities, laboratories, scientific research units, etc. for drying, baking, wax melting, and sterilization.
Model |
TR 6010/30(A) |
TR 6010/80(A) |
TR 6010/136(A) |
TR 6010/220(A) |
TR 6010/420A | TR 6010/620A | TR 6010/1000A |
Supply voltage | AC220V 50HZ | AC380V 50HZ | |||||
Temperature control range | RT+10~200℃/RT+10~250℃ | ||||||
Constant temperature fluctuation | ±1.0℃ | ||||||
Temperature resolution | 0.1℃ | ||||||
Temperature uniformity | ±3% (test point is 100°C) | ||||||
Operating ambient temperature | +5~40℃ | ||||||
Input power | 850W | 1550W | 2050W | 2450W | 3100W | 4000W | 5200W |
volume | 30L | 80L | 136L | 220L | 420L | 620L | 1000L |
Liner size (LxWxH) | 340mmx320mmx320mm | 450mmx400mmx450mm | 550mmx450mmx550mm | 600mmx500mmx750mm | 640mmx585mmx1355mm | 840mmx600mmx1355mm | 800mmx700mmx1590mm |
Dimensions (LxWxH) | 620mmx440mmx490mm | 740mmx530mmx630mm | 840mmx580mmx730mm | 880mmx630mmx930mm | 780mmx730mmx1780mm | 980mmx800mmx1880mm | 1050mmx880mmx2060mm |
Cargo carriers (Standard) | 2 pieces | 3 pieces | 4 pieces | 4 pieces | |||
Timing range | 0~9999min |
※The performance parameters are tested under no-load conditions: ambient temperature 20°C, ambient humidity 50%RH
Note: With "A" is a mirror stainless steel liner, without "A" is a galvanized sheet liner
· The inside of the box is made of mirror stainless steel argon arc welding, and the outside of the box is made of high-quality steel plate, which is beautiful and novel
· The microcomputer P.I.D. temperature controller with over-temperature deviation protection and digital display is adopted, with timing function, and the temperature control is accurate and reliable
· The hot air circulation system consists of a fan that can operate continuously at high temperatures and a suitable air duct to improve the temperature uniformity in the working room
The new synthetic silicon sealing strip is adopted, which can operate at high temperature for a long time, has a long service life and is easy to replace
· The air intake and exhaust volume in the chamber can be adjusted from the temperature control panel
· Independent temperature limit alarm system, automatic interruption when the limit temperature is exceeded, to ensure the safe operation of the experiment without accidents (optional)
· Can be equipped with a printer or RS485 interface for connecting to a printer or computer, and can record the change of temperature parameters (optional)