Qnix Coating Thickness Gauge can non-destructively measure the thickness of non-magnetic coatings (such as aluminum, chromium, copper, enamel, rubber, paint, etc.) on magnetic metal substrates (such as steel, iron, alloy and hard magnetic steel, etc.) and the thickness of non-conductive cladding (such as enamel, rubber, paint, plastic, etc.) on non-magnetic metal substrates (such as copper, aluminum, zinc, tin, etc.), which is an indispensable testing instrument for controlling and ensuring product quality, and is widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields.
Model | 4200/4200P | 4500/4500P |
Matrix | Fe | Fe/NFe |
Probe form | One, separate | |
Measuring range | 0-3000μm or 0-5000um | Fe: 0-3000 μm or 0-5000um NFe:0-3000μm |
Measurement accuracy | 0-3000μm:≤±(2+3%), 3000-5000μm≤±(2+5%) | |
Display accuracy | 0-99μm:0.1μm,100μm-999um:1um,999um以上,0.01mm | |
Operating temperature | -10 - +60℃ | |
Temperature compensation | 0-50℃ | |
Storage | / | |
Statistical functions | / | |
Overrun alarm | - | |
Minimal matrix | 10mm×10mm | |
Minimum curvature | Convex and concave radius: 3mm/25mm | |
Thinnest matrix | Fe:0.2mm,NFe:0.05mm | |
Electricity | 2 No. 5 batteries | |
Weight | 110g | |
Size | 110mm×60mm×27mm |
·Only need to be zeroed, no calibration required
·Fe/NFe dual-purpose probe
·All-in-one design
·Automatic power on/off
·Sound synchronization while measuring
·Ruby wear-resistant head with long life
·Backlight LED display, reading is clearer
·Automatic identification of the measurement substrate
·Temperature compensation
·Split probe to meet different measurement environments