在线客服

销售微信1
销售微信2
售后/技术
中文版English  

Color

TR 5402-82N Desktop Spectrophotometer

TR 5402-82N Desktop Spectrophotometer

The desktop spectrophotometer TR 5402/82N is an intelligent, convenient and accurate spectrophotometer, using TFT true color 7-inch capacitive touch screen, full spectrum, Android operating system. Illumination mode: reflection D/8°, transmission D/0° (including UV/UV exclusion measurement), accurate and stable measurement color, large storage capacity, powerful expansion function on the PC side, for laboratory color analysis and transmission.


Product model

TR 5402/82N

Lighting/Measurement Conditions

Reflection: D/8 (diffuse illumination, 8° direction reception)

SCI (with specular light) / SCE (without specular light) is measured simultaneously. Standards: CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, DIN5033 Teil7, JIS Z8722 Condition C, ASTM E1164, ASTM-D1003-07

Transmission: D/0 (diffuse illumination, vertical reception)

sensor

Silicon photodiode arrays

Spectroscopic method

Concave grating

Integrating sphere diameter

152mm

Measure the wavelength range

360nm-780nm

Measure wavelength intervals

10nm

Half wave width

5nm

Reflectance measurement range

0-200%, resolution 0.01%

Illumination light source

Pulsed xenon lamps and LEDs

Ultraviolet measurements

Including UV, 400nm cut-off, 420nm cut-off, 460nm cut-off

Measure the time

SCI or SCE mode < 2 seconds, SCI+SCE simultaneous measurement < 4 seconds

Illumination/measuring aperture

Reflection:

XLAV Φ25.4mm/Φ30mm  

LAVΦ15mm/Φ18mm  

MAVΦ8mm/Φ11mm  

SAVΦ3mm/Φ6mm  

Users can customize the caliber, and the caliber switch is automatically recognized

Transmission: Φ17mm/Φ25mm

Transmission Measurement Specifications

Sample width and height: unlimited, thickness: 50mm

repeatability

XLAV Spectral Reflectance/Transmittance: Within 0.1% of standard deviation

XLAV chromaticity value: standard deviation within 0.015 ΔE*ab (after instrument calibration, the white correction plate was measured 30 times at 10-second intervals)

Difference between stages

XLAV ΔE*ab 0.15 (based on BCRA Series 12 palette average measured at 23°C)

Standard observer

2° standard observer and 10° standard observer

Observe the light source

A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84

language

Chinese Simplified, English, Chinese Traditional, Russian, Spanish, Portuguese, Japanese, Thai, Korean, German, French, Polish

Display content

Spectral data, spectral diagrams, chromaticity data, chromatic aberration data, chromatic aberration diagrams, pass/fail judgments, simulated colors, color evaluations, haze, liquid chromaticity, color bias

Color space

L*a*b, L*C*h, Hunter Lab, Yxy, XYZ

Chromaticity indicator

WI (ASTM E313-00, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube, Berger Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Tint (ASTM E313-00), Metamerism Index Milm, Stain fastness, Colorchange fastness, ISO brightness, R457, A density, T density, E density, M density, APHA/Hazen/Pt-Co (platinum cobalt index), Gardner (Gardner index), Saybolt (Seibert index), ASTM color, haze, total transmittance, hiding power, force, strength

Chromatic aberration formula

ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔEab (Hunter), 555 hue classification

Storage space

8GB

Screen size

7-inch capacitive touch screen

operating system

Android

power supply

12V/3A

Operating temperature and humidity

5~40°C, no condensation below 80% relative humidity (at 35°C).

Store at temperature and humidity

 -20~45°C, no condensation below 80% relative humidity (at 35°C).

annex

Power adapter, data cable, transmission fixture, USB flash drive (including management software), black cavity, whiteboard, green board, 0% calibration shading cover, 30mm diameter plate, 18 mm diameter plate, 11 mm diameter plate, 6 mm diameter plate, support table, cuvette, damping handle

Optional accessories

Heating transmission fixture (including control circuit), vertical bracket, pneumatic ejector rod (including control circuit), small sample clamping accessories, reflective cuvette holder, corrosion-resistant protective plate (non-removable), fiber test box, film fixture, micro transmission fixture, 820N trolley box, 820N European standard plug, 820N American standard plug

interface

RS-232、USB、USB-B

volume

Length, width and height: 465x240x260mm

weight

10.8kg

other

1. Camera framing positioning

2. The instrument can be measured sideways, upwards and downwards (using accessories)

3. Automatic temperature and humidity compensation function


·Transmission D/0 structure and reflected D/8 structure

·Dual-path spectral analysis technology

·Compatible with SCI/SCE measurement, and support SCI+SCE simultaneous rapid measurement

·Equipped with Android operating system and rotatable capacitive touch screen

·Open transmission sample chamber to accommodate large sample sizes

·Abundant accessories: 15 kinds of standard accessories, 12 kinds of optional accessories, to meet the testing needs in different scenarios

·The instrument comes with a drawer for accessories protection and storage

·Reflection measurement aperture can be switched: four measuring calibers, the instrument automatically identifies the aperture and adjusts the optical path, saying goodbye to manual

·Four ultraviolet measurement modes make fluorescence hidden