The pendulum hardness tester produced by TRUIT is designed in accordance with GB/T 1730, ISO 1522 and ASTM D4366 standards. The KÖnig pendulum has the same principle as the Persoz pendulum and the double pendulum. The softer the pendulum contact with the coating surface, the faster the pendulum spokes attenuate, but the size, oscillation period and oscillation of the three are different.
The interaction between the pendulum and the paint film is complex and depends on the elastic and viscoelastic properties of the coating film, and there is no universal relationship between the results obtained by these three test methods. Only one type of pendulum is allowed in the specified damping time measurement.
In terms of the advantages of being a pendulum for a specific purpose, the following conditions can be used as a guideline:
a) On surfaces with a low friction factor, the Persoz pendulum may slip, which nullifies the result, which is rarely the case in the case of base coats and varnishes.
b) The three instruments reflect the sensitivity of the physical properties of the coating to its environment, so the test should be carried out under the condition of controlling the temperature and humidity without the influence of air flow, and the thickness of the paint film and the material of the substrate may also affect the damping time.
P摆
K摆
Model → Main technical parameters: ↓ | TR 5122 | TR 5120/K | TR 5120/P | TR 5120/KP |
Pendulum pin | Double pendulum | KÖnig single pendulum | Persoz single pendulum | Koenig + Persaz single pendulum |
Pendulum weight | 120g±0.5g | 200g±0.2g | 500g±0.1g | 200g±0.2g/500g±0.1g |
Ball diameter | 8mm | 5mm(0.2in) | 8mm(0.3in) | 5mm/8mm |
Initial swing angle | 5º | 6º | 12º | 6º/12º |
End swing angle | 2º | 3º | 4º | 3º/4º |
Oscillation period | 0.625s | 1.4s | 1s | 1.4s/1s |
Swing time on the glass plate | 440±6s | 250±10s | 430±10s | 250±10s/430±10s |
Counting function | automatic | automatic | automatic | automatic |
Dimensions (LxWxH) | 400mmx400mmx775mm |
·Touch screen control
·The pendulum needle is contracted by means of electromagnet
·It can be suitable for test boards with different thicknesses from 0.1mm~5.5mm
·Two laser probes are used to record data
·Plexiglass door cover, reducing air circulation and making it easy to view
·Different test methods can be switched freely